| -- Ac Drives -- |
| ---
F1500-G series (0.4~75kw) --- |
(Page up) |
|
 |
F1500-G series of AC drives is our newest product of general type. By blocking design, the measure of torque elevation is strengthened, the system function is enriched and the anti-jamming capacity and maneuverability is improved too. F1500-G series of AC drives is a kind of high-quality, multifunction, low-noise and large-torque genera-type AC drives that can meet wide-ranging application. Main Function
Special built-in PI adjuster for closed-loop control.
Controlled by keypad, 485 communication control box, PC and PLC, and 125 pieces of inverters
can be operated at the same time.
Line type, square curve type and user-defined type of torque-compensation available, adapted
to many kinds of loading mode
Jogging speed control, external analog signal speed control, multistage speed-control and code
timing speed control, PC or PLC speed control.
Current and voltage stalling adjustment provided
Standard Two-line type and three-line type of terminal control for more flexible manipulation.
User-defined analog input voltage signal and current signal all available, compound speed control
and channel switch between single and double realizable.
With the twinkling display of preset frequency, running frequency can be easily set before running,
especially on the stage of analog speed control. |
|
| ---
Performance Indexes --- |
Items |
Descriptions |
Input |
Rated Voltage |
three-phase 380V¡À15%single-phase 220V¡À15£¥£¨three-phase 220V¡À15£¥£© |
Rated Frequency |
50/60Hz£¨¡À5£¥£© |
Output |
Rated Voltage |
three-phase 0¡«380V; three-phase 0¡«220V |
Frequency Range |
0.00¡«400.0Hz (frequency resolution ratio0.01Hz) |
Overload Capacity |
150£¥¡¡60S |
Control Mode |
Frequency Setting Accuracy |
Digit Setting: 0.01Hz, Analog signal Setting: Max Frequency¡Á0.4£¥ |
Setting Mode |
optimized space vector control |
V/F Curve |
3 kinds of V/F curves. To select and set beeline V/F curve, polygonal line V/F curve and square V/F curve as per load |
Torque Promotion |
Manual setting torque promotion within 1¡«15£¥ |
Automatic Voltage Setting |
Automatic setting output voltage to meet input power fluctuation within certain range |
Braking Mode |
DC Braking£«Optimized Energy-consumption Braking |
PI Adjusting |
With built-in PI adjuster for automatic control |
Jogging |
Jogging Range: 0.00¡«400.0Hz |
Automatic Circular Running |
User will program output frequency mode as per process requirements |
Operation Functin |
Frequency Setting |
Digit frequency setting, keypad ¡°¡ø£¯¨‹¡± keys setting, ¡°UP¡± and ¡°DOWN¡± terminals setting; Keypad potentiometer or external analog signal (0¡«10V, 0¡«20mA) setting;
Analog channel compound operation setting;
Multi-stage speed control and coding speed control;
485 communication control box / computer setting. |
Start/Stop Control |
Control over keypad, 485 communication control box, terminals and computer |
Protection Function |
Input out-phase, input undervoltage, over-voltage, over-current, AC drives overload, motor overload, overheat, current check trouble, peripheral equipment trouble, user password error/exterior interference, contactor monitoring. |
Display |
LED nixie tube showing present output frequency, present rotate-speed, present output current, present output voltage, final axis linear-velocity, exterior pulse count-value, types of error, function-code parameters and operation parameters; 4 LED indicators showing the current working status of AC drives. |
Environment Conditions |
Equipment Location |
Free of tangy caustic gases or dust |
Environment Temperature |
-10¡æ¡«+50¡æ |
Environment Humidity |
Below 90% (no water-bead coagulation) |
VibrationStrength |
Below 0.5g (acceleration) |
height above sea level |
Below 1000 meters |
Applicable Motor Power |
0.4¡«75KW |
|
| (Page down) |
|
|