  --- F1500-G series (0.4~75kw) --- (Page up)
F1500-G series of AC drives is our newest product of general type. By blocking design, the measure of torque elevation is strengthened, the system function is enriched and the anti-jamming capacity and maneuverability is improved too. F1500-G series of AC drives is a kind of high-quality, multifunction, low-noise and large-torque genera-type AC drives that can meet wide-ranging application.
Main Function
Special built-in PI adjuster for closed-loop control.
Controlled by keypad, 485 communication control box, PC and PLC, and 125 pieces of inverters
can be operated at the same time.
Line type, square curve type and user-defined type of torque-compensation available, adapted
to many kinds of loading mode
Jogging speed control, external analog signal speed control, multistage speed-control and code
timing speed control, PC or PLC speed control.
Current and voltage stalling adjustment provided
Standard Two-line type and three-line type of terminal control for more flexible manipulation.
User-defined analog input voltage signal and current signal all available, compound speed control
and channel switch between single and double realizable.
With the twinkling display of preset frequency, running frequency can be easily set before running,
especially on the stage of analog speed control.
 --- Performance Indexes ---

Items

Descriptions

Input

Rated Voltage

three-phase 380V¡À15%single-phase 220V¡À15£¥£¨three-phase 220V¡À15£¥£©

Rated Frequency

50/60Hz£¨¡À5£¥£©

Output

Rated Voltage

three-phase 0¡«380V; three-phase 0¡«220V

Frequency Range

0.00¡«400.0Hz (frequency resolution ratio0.01Hz)

Overload Capacity

150£¥¡¡60S

Control Mode

Frequency Setting Accuracy

Digit Setting: 0.01Hz, Analog signal Setting: Max Frequency¡Á0.4£¥

Setting Mode

optimized space vector control

V/F Curve

3 kinds of V/F curves. To select and set beeline V/F curve, polygonal line V/F curve and square V/F curve as per load

Torque Promotion

Manual setting torque promotion within 1¡«15£¥

Automatic Voltage Setting

Automatic setting output voltage to meet input power fluctuation within certain range

Braking Mode

DC Braking£«Optimized Energy-consumption Braking

PI Adjusting

With built-in PI adjuster for automatic control

Jogging

Jogging Range: 0.00¡«400.0Hz

Automatic Circular Running

User will program output frequency mode as per process requirements

Operation Functin

Frequency Setting

Digit frequency setting, keypad ¡°¡ø£¯¨‹¡± keys setting, ¡°UP¡± and ¡°DOWN¡± terminals setting;
Keypad potentiometer or external analog signal (0¡«10V, 0¡«20mA) setting;
Analog channel compound operation setting;
Multi-stage speed control and coding speed control;
485 communication control box / computer setting.

Start/Stop Control

Control over keypad, 485 communication control box, terminals and computer

Protection Function

Input out-phase, input undervoltage, over-voltage, over-current, AC drives overload, motor overload, overheat, current check trouble, peripheral equipment trouble, user password error/exterior interference, contactor monitoring.

Display

LED nixie tube showing present output frequency, present rotate-speed, present output current, present output voltage, final axis linear-velocity, exterior pulse count-value, types of error, function-code parameters and operation parameters;
4 LED indicators showing the current working status of AC drives.

Environment Conditions

Equipment Location

Free of tangy caustic gases or dust

Environment Temperature

-10¡æ¡«+50¡æ

Environment Humidity

Below 90% (no water-bead coagulation)

VibrationStrength

Below 0.5g (acceleration)

height above sea level

Below 1000 meters

Applicable Motor Power

0.4¡«75KW